Spec is the promise.
Data is the proof.

Every peptide API is sourced from selected manufacturing partners, tested, and released against a published specification. Validated methods, ICH-aligned stability, and a signed Certificate of Analysis follow every lot — no exceptions, no shortcuts.

≥ 98%
Typical HPLC purity
100%
Lots shipped with COA
cGMP
Partner facilities
ICH Q1A
Stability program
— 01 / Method Validation

Every method proven before it releases a lot.

Our manufacturing partners qualify analytical methods per ICH Q2(R2) — specificity, linearity, accuracy, precision, LOD/LOQ, and robustness — before releasing commercial material. Validation packages are available under CDA where applicable.

  • HPLC-UVPurity & related substances
  • LC-MSIdentity confirmation
  • Karl FischerWater content
  • GC-HSResidual solvents (ICH Q3C)
  • LALBacterial endotoxin
  • ICP-MSElemental impurities (ICH Q3D)
Illustrative HPLC-UV · 214 nm
Example chromatogram — Semaglutide
Example data · not a lot-specific COA
8.62 min · 99.4%048121620mAUmin
99.4%
Main peak
0.6%
Total impurities
5
Peaks resolved
— 02 / Release Testing

Six checks. One signature. Zero exceptions.

Nothing leaves a partner facility until every panel result is on the COA and a qualified person has signed the release. If a single parameter falls off spec, the lot is quarantined — not shipped.

Illustrative release panel
Example QC coverage — validated methods
Example data · not a lot-specific COA
Identity
LC-MS
Conforms
Purity
HPLC-UV
99.4%
Water
Karl Fischer
3.1%
Residual solvents
GC-HS
< ICH Q3C
Endotoxin
LAL
< 0.5 EU/mg
Appearance
Visual
White powder
Illustrative lot-to-lot data
Example purity consistency across lots
Example specification ≥ 98.0%
98.098.599.099.5100.0L1L4L7L10L12
99.2%
Mean purity
σ 0.28
Std deviation
12/12
Lots on spec
— 03 / Lot Consistency

The number on the page is the number in the drum.

This example illustrates how lot-to-lot results can be reviewed against the same specification to assess consistency. Actual results are reported on the COA supplied for each lot.

Manufacturing partners hold retention samples for every lot. Historical COAs are available on request for material you've received from us.

— 04 / Stability

Every SKU on an ICH-aligned
stability program.

Manufacturing partners maintain long-term (5 °C ± 3 °C) and accelerated (25 °C / 60% RH) conditions per ICH Q1A(R2). Assay, related substances, water, and appearance are pulled at defined timepoints. Every lot carries a retest date on its Certificate of Analysis.

  • ●
    ICH Q1A(R2)
    Long-term & accelerated conditions
  • ●
    Retest dating
    Assigned per SKU, printed on every COA
  • ●
    Retention samples
    Held to end of retest + 12 months
  • ●
    Trending
    Reviewed at annual product review
Illustrative 24-month · 5 °C ± 3 °C
Example stability — assay retention & total impurities
Example data · not a stability report
0m3m6m9m12m18m24m%imp %
Assay retentionTotal impurities
— 05 / Certificate of Analysis

Every order. Every lot. Every time.

A specimen COA is shown below for format illustration only; its values do not describe an actual lot. The lot-specific document ships with every order and is traceable to raw materials, batch record, and the qualified person who released it.

Specimen Certificate of Analysis
SPECIMEN-001
ProductSemaglutide
LotSPECIMEN
ManufacturedYYYY-MM-DD
Retest dateYYYY-MM-DD
AppearanceWhite lyophilized powderpass
Identity (MS)Conformspass
Purity (HPLC)99.4%pass
Water (KF)3.1%pass
Endotoxin (LAL)< 0.5 EU/mgpass
Released by Quality Assurance (specimen)21 CFR 210/211
— 06 / Quality Governance

Independent QA. Documented controls. Audit-ready.

Manufacturing partners maintain quality review independent of production. Every batch record is reviewed, every deviation is investigated, and every customer complaint enters a formal CAPA system.

●
Partner facilities

Manufacturing partners operate FDA-registered facilities; registration does not imply FDA approval.

●
21 CFR 210 / 211

cGMP controls across receiving, synthesis, fill, release, and shipping.

●
Independent QA

Quality reports outside of operations; batch release requires QA sign-off.

●
Change control

Formal change-control and deviation systems with periodic review.

●
CAPA program

Every complaint tracked to root cause with documented corrective action.

●
Partner audits

Audit arrangements vary by manufacturing partner and product.